< WSW04 >

 

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

 

1

 

Earth function in transfer facility

0: Provided

1: Not provided

 

(Not used.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 2

3

 

 

 

2

 

Dual tone detection frequency

0

0: 350 and 440 Hz

(A)

 

0

1: 440 and 480 Hz

(B)

3

 

in ICM recording

 

1

0: 480 and 620 Hz

(C)

 

 

 

 

 

 

 

 

1

1: 480 and 620 Hz

(C)

 

 

 

 

 

 

 

 

 

4

 

Dual tone detection sensitivity

0: Normal

1: High

 

 

in ICM recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Length of time added to time

 

 

 

 

 

 

 

 

designated by selectors 3 and 4

 

 

 

 

 

 

5

 

on the WSW 24 (time between

0: Not added

1: +4 seconds added

 

 

 

CML ON and pseudo ring

 

 

 

 

 

 

 

 

backtone return).

 

 

 

 

 

 

 

 

 

No. 6

7

8

 

 

 

 

 

 

0

0

0: 80 ms

 

 

 

6

 

 

0

0

1: 100 ms

 

 

 

Break time length for flash

0

1

0: 110 ms

 

 

 

0

1

1: 120 ms

 

 

 

function

 

 

8

 

1

0

0: 200 ms

 

 

 

 

 

 

 

 

 

1

0

1: 250 ms

 

 

 

 

 

1

1

0: 500 ms

 

 

 

 

 

1

1

1: 700 ms

 

 

 

 

 

 

 

 

 

 

Note:

-Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is supported.

-Selectors 2 through 4 are applicable to models equipped with built-in TADs.

-Selector 1: Earth function in transfer facility (Not used.)

This selector determines whether or not the earth function is added to the transfer setting menu to be accessed by the function switch.

- Selectors 2 and 3: Dual tone detection frequency in ICM recording

If the machine detects either of the frequencies set by these selectors in ICM recording, it disconnects the line. For example, if these selectors are set to “0, 0” the machine disconnects the line upon detection of 350 Hz or 440 Hz.

- Selector 4: Dual tone detection sensitivity in ICM recording

Setting this selector to “1” increases the tone detection sensitivity in ICM recording.

- Selectors 6 and 8: Break time length for flash function

These selectors set the break time length. This setting is effective only when the flash function is selected for the Search/Speed Dial button by using the function switch.

App. 1-8