(4) Remove the three cup B M3x10 Taptite screws, and then remove the Hinge ASSY L.
Taptite, cup B M3x10
Hinge ASSY L
<Bottom>
ADF unit
Fig. 3-61
(5)Place the ADF unit the correct way up, and then remove the ADF cover ASSY from the ADF unit.
ADF cover ASSY
ADF unit
Fig. 3-62