1.4.16Acquisition of White Level Data and CCD Scanner Area Setting (Function code 55)

<Function>

This function allows the machine to obtain white level data for the CCD scanner and save it together with the CCD scanner area into the EEPROM on the main PCB.

Note:

Always implement this operation when replacing the CCD unit, scanner unit or main PCB.

<Operating Procedure>

(1)Press the 5 button twice in the initial stage of the maintenance mode. The “SCANNER AREA SET” will appear on the LCD.

(2)When setting of the scanner area is completed, a 4-digit number will appear on the LCD. (e.g., 4723)

*If you press the Stop/Exit button at this point, the machine will beep for one second and return to the initial stage of the maintenance mode.

Enter the input data value of a 5-digit number based on the 4-digit number to be displayed referring to the table below. (e.g., 4723 Æ 47247)

(3)The machine saves the magnification compensation setting value into the EEPROM, and then it beeps for one second and returns to the initial stage of the maintenance mode.

 

Maintenance mode 55 required input data

 

Input data

 

 

 

 

 

 

1

4610

---

4619

46156

2

4620

---

4629

46257

3

4630

---

4639

46358

4

4640

---

4649

46459

5

4650

---

4659

46550

6

4660

---

4669

46651

7

4670

---

4679

46752

8

4680

---

4689

46853

9

4690

---

4699

46954

10

4700

---

4709

47056

11

4710

---

4719

47157

12

4720

---

4729

47247

13

4730

---

4739

47359

14

4740

---

4749

47450

15

4750

---

4759

47551

16

4760

---

4769

47652

17

4770

---

4779

47753

18

4780

---

4789

47854

19

4790

---

4799

47955

20

4800

---

4809

48057

21

4810

---

4819

48158

22

4820

---

4829

48259

23

4830

---

4839

48350

5-25

Confidential