< WSW18 >

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

1

Not used.

 

 

 

 

 

 

 

 

 

 

No. 2

3

 

2

Detection enabled time for CNG

0

0: 40 sec.

 

0

1: 0 sec. (No detection)

3

and no tone

1

0: 5 sec.

 

 

 

 

 

 

1

1: 80 sec.

 

 

 

 

 

 

4

Not used.

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

6

Registration of station ID

0: Permitted

1: Prohibited

 

 

 

 

 

 

 

No. 7

8

 

 

 

0

0: No monitoring

7

 

0

1: No monitoring

Tone sound monitoring

1

0: Up to phase B at the calling

 

8

 

station only

 

 

 

 

1

1: All transmission phases both

 

 

 

at the calling and called

 

 

 

stations

 

 

 

 

 

 

- Selectors 2 and 3: Detection enabled time for CNG and no tone

After the line is connected via the external telephone or by picking up the handset of the machine, the machine can detect a CNG signal or no tone for the time length specified by these selectors. The setting specified by these selectors becomes effective only when selector 8 on WSW20 is set to “1.”

- Selector 6: Registration of station ID

Setting this selector to “0” permits the registration of station ID for Austrian and Czech models.

- Selectors 7 and 8: Tone sound monitoring

These selectors set monitoring specifications of the tone sound inputted from the line.

App. 1-23

Confidential