Selector No. | Function |
| Setting and Specifications | ||
|
|
|
|
| |
1 | Not used. |
|
|
| |
|
|
|
|
| |
|
| No. 2 | 3 |
| |
2 | Detection enabled time for CNG | 0 | 0: 40 sec. |
| |
0 | 1: 0 sec. (No detection) | ||||
3 | and no tone | ||||
1 | 0: 5 sec. |
| |||
|
|
| |||
|
| 1 | 1: 80 sec. |
| |
|
|
|
|
| |
4 | Not used. |
|
|
| |
5 |
|
|
| ||
|
|
|
| ||
|
|
|
| ||
6 | Registration of station ID | 0: Permitted | 1: Prohibited | ||
|
|
|
|
| |
|
| No. 7 | 8 |
| |
|
| 0 | 0: No monitoring | ||
7 |
| 0 | 1: No monitoring | ||
Tone sound monitoring | 1 | 0: Up to phase B at the calling | |||
| |||||
8 |
| station only | |||
|
| ||||
|
| 1 | 1: All transmission phases both | ||
|
|
| at the calling and called | ||
|
|
| stations |
| |
|
|
|
|
|
- Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the machine, the machine can detect a CNG signal or no tone for the time length specified by these selectors. The setting specified by these selectors becomes effective only when selector 8 on WSW20 is set to “1.”
- Selector 6: Registration of station ID
Setting this selector to “0” permits the registration of station ID for Austrian and Czech models.
- Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.
App. | Confidential |