Error code 68
Print Unable 68
Turn the power off and then back on again.
Fuser unit failure (The side thermistor detects higher temperature than the specified value.)
Error code 69
Print Unable 69
Turn the power off and then back on again.
Fuser unit failure (The side thermistor detects lower temperature than the specified value.)
Error code 6APrint Unable 6A
Turn the power off and then back on again.
Fuser unit failure (The side thermistor does not detect 60°C within the specified time.)
Error code 6BPrint Unable 6B
Turn the power off and then back on again.
Fuser unit failure (The center thermistor does not detect 100°C within the specified time.)
Error code 6CPrint Unable 6C
Turn the power off and then back on again.
Fuser unit failure (The center thermistor detects higher temperature than the specified value.)
Error code 6DPrint Unable 6D
Turn the power off and then back on again.
Fuser unit failure (The center thermistor detects lower temperature than the specified value.)
Error code 6EPrint Unable 6E
Turn the power off and then back on again.
Fuser unit failure (The center thermistor does not detect temperature rising within the specified time.)
Error code 6FPrint Unable 6F
Turn the power off and then back on again.
Fuser unit failure (The center and side thermistors detect extremely high temperature.)
Step | Cause | Remedy |
1 | Fuser unit failure | Replace the fuser unit. |
2 | Replace the PS PCB unit. | |
| PCB failure |
|
3 | Engine PCB failure | Replace the engine PCB ASSY. |
Confidential |