Speaker is silent during on-hook dialing.

Step

Possible cause

Check

Result

Remedy

 

 

 

 

 

1

Connection

Are the main PCB and

No

Reconnect the connector

 

between main

speaker connected

 

properly.

 

PCB and speaker

properly?

 

 

2

Speaker

Is the problem solved

Yes

Replace the Speaker.

 

 

after replacing the

 

 

 

 

speaker?

 

 

3

Connection

Are the main PCB and

No

Reconnect the connector

 

between main

NCU PCB connected

 

properly.

 

PCB and NCU

properly?

 

 

 

PCB

 

 

 

4

Harness between

Is the harness damaged?

Yes

Replace the harness with

 

main PCB and

 

 

a normal one.

 

NCU PCB

 

 

 

5

Connection

Are the main PCB and

No

Reconnect the connector

 

between main

control panel PCB

 

properly.

 

PCB and control

connected properly?

 

 

 

panel PCB

 

 

 

6

Harness between

Is the harness damaged?

Yes

Replace the harness with

 

main PCB and

 

 

a normal one.

 

control panel PCB

 

 

 

7

NCU PCB

Is the problem solved

Yes

Replace the NCU PCB

 

 

after replacing the NCU

 

ASSY.

 

 

PCB ASSY?

 

 

8

Main PCB

Is the problem solved

Yes

Replace the main PCB

 

 

after replacing the main

 

ASSY.

 

 

PCB ASSY?

 

 

Dialing function does not switch between "tone" and "pulse".

Step

Possible cause

Check

Result

Remedy

 

 

 

 

 

1

Connection

Are the main PCB and

No

Reconnect the connector

 

between main

NCU PCB connected

 

properly.

 

PCB and NCU

properly?

 

 

 

PCB

 

 

 

2

Harness between

Is the harness damaged?

Yes

Replace the harness with

 

main PCB and

 

 

a normal one.

 

NCU PCB

 

 

 

3

NCU PCB

Is the problem solved

Yes

Replace the NCU PCB

 

 

after replacing the NCU

 

ASSY.

 

 

PCB ASSY?

 

 

4

Main PCB

Is the problem solved

Yes

Replace the main PCB

 

 

after replacing the main

 

ASSY.

 

 

PCB ASSY?

 

 

 

 

 

 

 

1-69