8.TROUBLESHOOTING OF THE CONTROL PANEL

Nothing is displayed on the LCD.

User Check

- Verify if the power switch is turned off.

Step

Possible cause

Check

Result

Remedy

 

 

 

 

 

1

Connection

Are the main PCB and

No

Reconnect the connector

 

between main

control panel PCB

 

properly.

 

PCB and control

connected properly?

 

 

 

panel PCB

 

 

 

2

Harness between

Is the harness damaged?

Yes

Replace the harness with

 

main PCB and

 

 

a normal one.

 

control panel PCB

 

 

 

3

Connection

Are the main PCB and PS

No

Reconnect the connector

 

between main

PCB unit connected

 

properly.

 

PCB and PS PCB

properly?

 

 

 

unit

 

 

 

4

Harness between

Is the harness damaged?

Yes

Replace the harness with

 

main PCB and PS

 

 

a normal one.

 

PCB unit

 

 

 

5

LCD

Is the problem solved

Yes

Replace the LCD.

 

 

after replacing the LCD?

 

 

6

Control panel

Is the problem solved

Yes

Replace the control panel

 

PCB

after replacing the control

 

PCB.

 

 

panel PCB?

 

 

7

PS PCB unit

Is the problem solved

Yes

Replace the PS PCB unit.

 

 

after replacing the PS

 

 

 

 

PCB unit?

 

 

8

Main PCB

Is the problem solved

Yes

Replace the main PCB

 

 

after replacing the main

 

ASSY.

 

 

PCB ASSY?

 

 