< WSW35 >

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

No. 1

2

3

4

1

 

0

0

0

0: No detection

Max. detection period of dial

0

0

0

1: 1 sec.

tone/busy tone during recording

0

0

1

0: 2 sec.

4

of ICM

0

1

0

0: 4 sec.

 

 

 

 

 

 

 

 

1

1

1

1: 15 sec.

 

 

 

 

 

 

5

 

 

 

 

 

Not used.

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

Note:

Selectors 1 through 4 are applicable to models equipped with internal TADs.

- Selectors 1 through 4: Max. detection period of dial tone/busy tone during recording of

ICM

If the machine (called station) detects dial tone or busy tone exceeding the detection level specified by selectors 1 through 3 on WSW30 for the period specified by these selectors, then it disconnects the line.

< WSW36 >

 

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

1

 

ECP mode* (Not used.)

0: ON

 

1: OFF

 

 

 

 

 

 

 

2

 

Recovery from Inactive PC

0: Disable

1: Enable

 

 

Interface (Not used.)

 

 

 

 

 

 

 

 

 

 

 

 

3

 

PC Power-off Recognition Time

0: Normal

1: Long

 

 

(Not used.)

 

 

 

 

 

 

 

 

 

 

 

 

4

 

Not used.

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Escape from phase C

0: Yes

 

1: No

 

 

 

 

 

 

 

 

 

 

 

 

No. 6

7

8

 

 

 

 

 

0

0

0: 0

(Ignored)

 

 

 

 

0

0

1: 4

(448 Hz)

 

6

 

Extension of incoming calling

0

1

0: 8

(244 Hz)

 

 

signal (CI) frequency band

0

1

1: 12

(162 Hz)

 

 

specified by selectors 1 through

 

8

 

1

0

0: 16

(122 Hz)

 

 

4 on WSW14

 

 

 

 

1

0

1: 20

(97 Hz)

 

 

 

 

1

1

0: 24

(81 Hz)

 

 

 

 

1

1

1: 28

(69 Hz)

 

 

 

 

 

 

 

 

*ECP (Enhanced Capabilities Port)

NOTE:

Selectors 2 and 3 will become operative if selectors 1 and 2 of WSW46 are set to “monitor” the PC power ON/OFF state.

App. 1-40

Confidential