< WSW22 >

 

Selector No.

Function

Setting and Specifications

 

 

 

 

 

 

 

1

 

ECM* in sending

0: Valid

1: Invalid

 

 

 

 

 

 

 

2

 

ECM* in receiving

0: Valid

1: Invalid

 

 

 

 

 

 

 

3

 

Call Waiting Caller ID

0: Displayed

1: Not displayed

 

 

 

 

 

 

 

4

 

Not used.

 

 

 

 

 

 

 

 

 

5

 

Acceptable TCF bit error rate

0: 0 %

1: 8 %

 

 

0: 0 %

1: 4 %

 

 

 

 

 

(%) (Only at 4800 bps)

 

 

0: 0 %

1: 2 %

 

8

 

(Not used.)

 

 

0: 0 %

1: 1 %

 

 

 

 

 

 

 

 

 

 

 

 

 

* ECM: Error correction mode

Note:

-Selector 3 is applicable to the American models only.

-Selectors 5 through 8 are applicable to the Chinese, Taiwanese and Asian models only.

-Selector 3: Call Waiting Caller ID

Setting this selector to “0” allows the user to decide whether or not to interrupt the current call when a new call comes in. If Call Waiting Caller ID service is available in the area and the user subscribes to it, he/she can see information about his/her incoming call on the LCD.

- Selectors 5 through 8: Acceptable TCF bit error rate (%) (Not used.)

Setting two or more selectors to “1” produces addition of percent assigned to each selector. If you set selectors 7 and 8 to “1,” the acceptable TCF bit error rate will be 3%.