| Selector No. | Function | Setting and Specifications | ||
|
|
|
|
|
|
| 1 |
| ECM* in sending | 0: Valid | 1: Invalid |
|
|
|
|
|
|
| 2 |
| ECM* in receiving | 0: Valid | 1: Invalid |
|
|
|
|
|
|
| 3 |
| Call Waiting Caller ID | 0: Displayed | 1: Not displayed |
|
|
|
|
|
|
| 4 |
| Not used. |
|
|
|
|
|
|
|
|
| 5 |
| Acceptable TCF bit error rate | 0: 0 % | 1: 8 % |
|
| 0: 0 % | 1: 4 % | ||
|
|
| |||
|
| (%) (Only at 4800 bps) | |||
|
| 0: 0 % | 1: 2 % | ||
| 8 |
| (Not used.) | ||
|
| 0: 0 % | 1: 1 % | ||
|
|
| |||
|
|
|
| ||
|
|
|
|
|
|
* ECM: Error correction mode
Note:
-Selector 3 is applicable to the American models only.
-Selectors 5 through 8 are applicable to the Chinese, Taiwanese and Asian models only.
-Selector 3: Call Waiting Caller ID
Setting this selector to “0” allows the user to decide whether or not to interrupt the current call when a new call comes in. If Call Waiting Caller ID service is available in the area and the user subscribes to it, he/she can see information about his/her incoming call on the LCD.
- Selectors 5 through 8: Acceptable TCF bit error rate (%) (Not used.)
Setting two or more selectors to “1” produces addition of percent assigned to each selector. If you set selectors 7 and 8 to “1,” the acceptable TCF bit error rate will be 3%.