< WSW29 >

 

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

 

 

 

 

No. 1

2

3

 

 

 

 

 

0

0

0: -47.0 dBm

(A)

 

1

 

Compression threshold level for

0

0

1: -48.5 dBm

(B)

 

 

0

1

0: -50.0 dBm

(C)

 

 

voice signals inputted via the

0

1

1: -51.5 dBm

(D)

 

 

telephone line in the built-in

 

3

 

1

0

0: -53.0 dBm

(E)

 

 

TAD operation

 

 

 

 

1

0

1: -54.5 dBm

(F)

 

 

 

 

1

1

0: -56.0 dBm

(G)

 

 

 

 

1

1

1: OFF

(H)

 

 

 

 

No. 4

5

6

 

 

 

 

 

0

0

0: -44.0 dBm

(A)

 

4

 

Compression threshold level for

0

0

1: -45.5 dBm

(B)

 

 

0

1

0: -47.0 dBm

(C)

 

 

voice signals inputted via the

0

1

1: -48.5 dBm

(D)

 

 

handset in the built-in TAD

 

6

 

1

0

0: -50.0 dBm

(E)

 

 

operation

 

 

 

 

1

0

1: -51.5 dBm

(F)

 

 

 

 

1

1

0: -53.0 dBm

(G)

 

 

 

 

1

1

1: OFF

(H)

 

7

 

Impedance switching control in

0: OFF

1: ON

 

 

pulse dialing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prompt beep when the memory

 

 

 

 

 

8

 

area for the activity report

0: No

1: Yes

 

 

 

becomes full

 

 

 

 

 

 

 

 

 

 

 

 

Note:

-Selectors 1 through 6 are applicable to models equipped with built-in TADs.

-Selectors 7 and 8 are applicable only to the European versions.

-Selectors 1 through 6: Compression threshold level for voice signals inputted via the telephone line in the built-in TAD operation

If voice signals inputted via the telephone line are below the level specified by these selectors, the TAD interprets those received voice signals as no signal, compressing the recording time.

- Selector 8: Prompt beep for activity report

This selector determines whether or not to beep if the memory area for the activity report becomes full, for prompting you to print out the report. (Printing it out will clear the memory area.)

App. 1-34

Confidential