| Selector No. | Function |
| Setting and Specifications | |||
|
|
|
|
|
|
|
|
|
|
|
| No. 1 | 2 | 3 |
|
|
|
|
| 0 | 0 | 0: | (A) |
| 1 |
| Compression threshold level for | 0 | 0 | 1: | (B) |
|
| 0 | 1 | 0: | (C) | ||
|
| voice signals inputted via the | 0 | 1 | 1: | (D) | |
|
| telephone line in the | |||||
| 3 |
| 1 | 0 | 0: | (E) | |
|
| TAD operation | |||||
|
|
|
| 1 | 0 | 1: | (F) |
|
|
|
| 1 | 1 | 0: | (G) |
|
|
|
| 1 | 1 | 1: OFF | (H) |
|
|
|
| No. 4 | 5 | 6 |
|
|
|
|
| 0 | 0 | 0: | (A) |
| 4 |
| Compression threshold level for | 0 | 0 | 1: | (B) |
|
| 0 | 1 | 0: | (C) | ||
|
| voice signals inputted via the | 0 | 1 | 1: | (D) | |
|
| handset in the | |||||
| 6 |
| 1 | 0 | 0: | (E) | |
|
| operation | |||||
|
|
|
| 1 | 0 | 1: | (F) |
|
|
|
| 1 | 1 | 0: | (G) |
|
|
|
| 1 | 1 | 1: OFF | (H) |
| 7 |
| Impedance switching control in | 0: OFF | 1: ON | ||
|
| pulse dialing | |||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Prompt beep when the memory |
|
|
|
|
| 8 |
| area for the activity report | 0: No | 1: Yes | ||
|
|
| becomes full |
|
|
|
|
|
|
|
|
|
|
|
|
Note:
-Selectors 1 through 6 are applicable to models equipped with
-Selectors 7 and 8 are applicable only to the European versions.
-Selectors 1 through 6: Compression threshold level for voice signals inputted via the telephone line in the
If voice signals inputted via the telephone line are below the level specified by these selectors, the TAD interprets those received voice signals as no signal, compressing the recording time.
- Selector 8: Prompt beep for activity report
This selector determines whether or not to beep if the memory area for the activity report becomes full, for prompting you to print out the report. (Printing it out will clear the memory area.)