2.PERIODICAL REPLACEMENT PARTS2.1Periodical Replacement Parts

Periodical replacement parts are the parts to be replaced periodically to maintain product quality. These parts would affect the product quality if they loose their functionality even if they do not appear to be damaged or there is no change in their appearance.

The periodical replacement parts listed in the table below should be replaced according to the service life.

Parts Name

LCD

Q’ty

Approximate Life

Replacement

Procedure

 

 

 

 

Fuser unit &

Fuser Unit

1

80,000 pages

Refer to 2.2.1.

Toner filter frame ASSY

 

 

 

 

 

 

 

 

 

Laser unit

Laser Unit

1

100,000 pages

Refer to 2.2.2.

 

 

 

 

 

Paper feeding kit *1

PF Kit 1, PF Kit 2

1

100,000 pages

Refer to 2.2.3.

MP paper feeding kit *2

PF Kit MP

1

50,000 pages

Refer to 2.2.4.

*1: The paper feeding kit includes the separation pad ASSY, separation pad spring and roller holder ASSY.

*2: MP Paper feeding kit includes the separation pad ASSY MP, separation pad spring MP, and MP roller holder ASSY.

When replacing the periodical replacement parts, each of the counters need to be reset in order to count the number of replacement times. Refer to “2.3 Parts Life Reset Function” in this chapter.

Also make sure to wipe the dirt on the drum unit as shown in the figure below when replacing each of the periodical replacement parts.

The number of printed pages of the machine can be checked by accessing the machine’s log information on the LCD. (Refer to “1.4.23 Display of the Machine’s Log Information” (Function code 80) in Chapter 5.) The actual number of printed page will vary depending on the type of print job or the paper to being used. The figures indicated as the approximate life in the table above are worked out when printing a general business document (with 5% print coverage) on one side of A4-size paper.

Note:

-Always turn off the power switch of the machine and unplug the power cord from the power outlet before replacing the periodical replacement parts.

-If the fuser unit is replaced after errors related to the fuser unit occur, it is necessary to leave the machine power ON for ten minutes after part replacement. This will make the machine to be released from errors.

-After disconnecting flat cables, check that each cable is not damaged at its end or short- circuited.

-When connecting flat cables, do not insert them at an angle. After insertion, check that the cables are not at an angle.

2-4

Confidential