< WSW53 >

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

1

Not used.

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 3

4

 

3

Caller ID (number display) FSK

0

0: 0 ms

 

0

1: 100 ms

 

4

receiving timing delay setting

 

1

0: 150 ms

 

 

 

 

 

 

1

1: 200 ms

 

 

 

 

 

 

 

 

No. 5

6

 

5

Caller ID (number display)

0

0: 20 ms

 

instantaneous interrupt

0

1: 10 ms

 

6

 

detection time setting

1

0: 30 ms

 

 

 

 

 

1

1: 0 ms

 

 

 

 

 

 

7

CNG detection retry after invalid

0: Yes

1: No

CNG detected

 

 

 

 

 

 

 

 

8

Decompression of JPEG

0: ASIC

1: Software

compressed file (Not used.)

 

(Default)

 

 

 

 

 

 

 

 

 

Note:

Selector 8 is applicable only to models equipped with photo media capture.

-Selectors 3 through 6: Caller ID (number display) FSK receiving timing delay setting and instantaneous interrupt detection time setting

If a call error occurs during use of caller ID (number display), it may be possible for the error to be corrected by adjustment these selectors. If the error cannot be thus corrected, try adjusting selectors 5 and 6.

- Selector 8: Decompression of JPEG compressed file (Not used.)

Decompress JPEG compressed files stored on the inserted memory card. (ASIC: application specified integrated circuit)., JPEG compressed files can be decompressed with an ASIC. If an image fails to be replayed correctly due to a decompression error, set this selector to “1” and use other proven decompression software instead.

App. 1-58

Confidential