< WSW54 >

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

No. 1

2

 

1

 

0

0: 100 ms (default)

PictBridge command delay time

0

1: 0 ms

 

2

 

 

1

0: 50 ms

 

 

 

 

 

 

1

1: 200 ms

 

 

 

 

 

 

3

More CNG detection cycles in

0: No

1: 2 more cycles

user-friendly reception

 

 

 

 

4

Cordless handset ID recovery

0: Valid

1: Invalid

future

 

 

 

 

 

 

 

 

 

 

 

No. 5

6

 

5

Caller ID tone alert detection

0

0: 10 ms (default)

0

1: 20 ms

 

6

time length (Not used.)

 

1

0: 30 ms

 

 

 

 

 

 

1

1: 40 ms

 

 

 

 

 

7

Caller ID mild pulse

0: Yes

1: No

transmission (Not used.)

 

(default)

 

 

 

 

 

 

 

 

 

Switching between DTMF and

0: DTMF

1: FSK

8

FSK for caller ID reception

 

(default)

 

 

(Not used.)

 

 

 

Note:

 

 

 

 

-Selectors 1 and 2 are applicable only to models equipped with PictBridge.

-Selector 4 is applicable only to models equipped with cordless handset(s).

-Selectors 5 through 7 are applicable only to models designed for the UK market.

-Selector 8 is applicable only to models designed for the Chinese market.

-Selector 1 and 2: PictBridge command delay time

These selectors specify the PictBridge command delay time that applies when the machine responds to the digital camera connected via PictBridge during negotiation. If the machine fails to receive data from the digital camera, change the delay time.

- Selector 3: More CNG detection cycles in user-friendly reception

If CNG detection fails even after adjustment of selectors 4 and 5 on WSW26, try adding 2 more cycles to the permitted number of CNG detection cycles.

- Selector 4: Cordless handset ID recovery

When this function becomes operative, if the cordless handset ID number registered on the main board does not match that registered on the cordless board, the cordless handset ID number registered on the main board will be automatically written onto the cordless board.

- Selectors 5 and 6: Caller ID tone alert detection time length (Not used)

In the event of a false detection of a caller ID tone alert, adjust the detection time length.

- Selector 7: Caller ID mild pulse transmission (Not used.)

If a caller ID (number display) cannot be displayed due to mild pulses transmitted after detection of tone alert, use this selector so as to make it impossible to transmit mild pulses.

App. 1-59

Confidential