Selector No. | Function |
| Setting and Specifications | |||
|
|
|
|
|
| |
|
| No. 1 | 2 |
|
| |
1 | Frequency band selection | 0 | 0: 13 Hz | |||
(lower limit) for incoming calling | 0 | 1: 15 Hz | ||||
2 | ||||||
signal (CI) | 1 | 0: 23 Hz | ||||
| ||||||
|
| 1 | 1: 20 Hz | |||
|
|
|
|
|
| |
|
| No. 3 | 4 |
|
| |
3 | Frequency band selection | 0 | 0: 30 Hz | |||
(upper limit) for incoming calling | 0 | 1: 55 Hz | ||||
4 | ||||||
signal (CI) | 1 | 0: 70 Hz | ||||
| ||||||
|
| 1 | 1: 200 Hz | |||
|
|
|
|
|
| |
|
| No. 5 | 6 | 7 | 8 | |
|
| 0 | 0 | 0 | 0: Fixed to once | |
|
| 0 | 0 | 0 | 1: 1 to 6 times | |
|
| 0 | 0 | 1 | 0: 1 to 8 times | |
|
| 0 | 0 | 1 | 1: 2 to 8 times | |
|
| 0 | 1 | 0 | 0: 1 to 2 times | |
5 |
| 0 | 1 | 0 | 1: 1 to 3 times | |
No. of rings in AUTO ANS | 0 | 1 | 1 | 0: 1 to 4 times | ||
0 | 1 | 1 | 1: 1 to 5 times | |||
mode | ||||||
8 | 1 | 0 | 0 | 0: 2 to 3 times | ||
| ||||||
|
| 1 | 0 | 0 | 1: 2 to 4 times | |
|
| 1 | 0 | 1 | 0: 2 to 5 times | |
|
| 1 | 0 | 1 | 1: 2 to 6 times | |
|
| 1 | 1 | 0 | 0: 1 to 10 times | |
|
| 1 | 1 | 0 | 1: 2 to 10 times | |
|
| 1 | 1 | 1 | 0: 3 to 5 times | |
|
| 1 | 1 | 1 | 1: 4 to 10 times | |
|
|
|
|
|
|
- Selectors 1 through 4: Frequency band selection for incoming calling signal (CI)
These selectors are used to select the frequency band of CI for activating the AUTO ANS facility.
In the French models, if the user sets the PBX to OFF from the control panel, the setting made by selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even if the setting made by these selectors does not apply, it will be printed on the configuration list.)
- Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.
App. | Confidential |