(11)Remove the double-faced adhesive tape which is attached between the FFC cable ASSY and CCD unit, and disconnect the FFC cable ASSY from the CCD unit.

Note:

-After disconnecting the flat cable(s), check that each cable is not damaged at its end or short-circuited.

-When connecting the flat cable(s), do not insert it at an angle. After insertion, check that the cable is not at an angle.

CCD unit

Connector

FFC cable ASSY

Double-faced adhesive tape

Fig. 3-137

(12) Push the Pulley ASSY to the direction of the arrow 12a and remove the CCD drive belt.

CCD drive belt

12b12a

Pulley ASSY

Fig. 3-138

3-108

Confidential