(10) Video signal reception

 

Code 1

Code 2

Causes

 

A0

03

Error correction sequence not terminated even at the final

 

 

 

transmission speed for fallback.

 

A0

11

Receive buffer empty. (5-second time-out)

 

A0

12

Receive buffer full during operation except receiving into memory.

 

A0

13

Decoding error continued on 500 lines or more.

 

A0

14

Decoding error continued for 10 seconds or more.

 

A0

15

Time-out: 13 seconds or more for one-line transmission.

 

A0

16

RTC not found or carrier OFF detected for 6 seconds.

 

 

 

 

 

A0

17

RTC found but no command detected for 60 seconds or more.

 

 

 

 

 

A0

19

No video data to be sent

 

 

 

 

 

A8

01

RTN, PIN, or ERR received at the calling terminal. *

 

 

 

 

 

A9

01

RTN, PIN, or ERR received at the called terminal. *

 

 

 

 

 

AA

18

Receive buffer full during receiving into memory.

 

 

 

 

 

 

 

* Available in German models only

(11) General communications-related

 

 

 

 

 

Code 1

Code 2

Causes

 

B0

02

Unable to receive the next-page data.

 

 

 

 

 

B0

03

Unable to receive polling even during turn-around

 

 

 

transmission due to call reservation.

 

B0

04

PC interface error.

 

BF

01

Communication canceled by pressing the Stop/Exit button

 

 

 

before establishment of FAX communication*.

 

BF

02

Communication canceled by pressing the Stop/Exit button

 

 

 

after establishment of FAX communication*.

 

BF

03

Transmission canceled due to a scanning error caused by no

 

 

 

document or document feed problem in ADF scanning in real

 

 

 

time transmission.

*Establishment of FAX communication:

FAX communication is established when the calling station receives a DIS (reception capability) signal from the called station and the called station receives a NSS or DCS (communications test) signal from the calling station.

(12)Maintenance mode

 

Code 1

 

Code 2

Causes

 

 

 

 

 

 

E0

 

01

Failed to detect 1300 Hz signal in burn-in operation.

 

 

 

 

 

 

E0

 

02

Failed to detect PB signals in burn-in operation.

 

 

 

 

 

 

 

 

 

 

(13) Equipment error

 

 

 

 

 

 

 

Code 1

 

Code 2

Causes

 

 

 

 

 

 

FF

 

X X

Equipment error

 

 

 

 

(For X X, refer to “2.1 Error Indication”)

 

 

 

 

 

1-63

Confidential