2.OTHER SERVICE FUNCTIONS

2.1Resetting the Periodical Replacement Parts Life

2.1.1Resetting the Life Counter of the Belt Unit <Function>

This function allows you to reset the page counter of the belt unit and increase the number of replacement times by one.

<Operating Procedure>

(1)Press the 3 and 9 buttons at the same time in the ready state. The “Reset Menu” will appear on the LCD.

(2)Press the button a few times to select “Belt unit”.

(3)Press the OK button.

The “1. Reset 2. Exit” will appear on the LCD.

(4)Press the 1 button when resetting the page counter of the belt unit. Press the 2 button if not resetting.

(5)The “Belt unit / Accepted” will appear on the LCD if pressing the 1 button. The page counter of the belt unit is reset, and the number of replacement times is increased by one. Then, the machine returns to the ready state.

If pressing the 2 button, the machine returns to the Belt unit and you need to press Stop/Exit button to go back to the ready state without performing any operation.

2.1.2Resetting the Life Counter of the Fuser Unit <Function>

This function allows you to reset the page counter of the fuser unit and increase the number of replacement times by one.

<Operating Procedure>

(1)Press the 3 and 9 buttons at the same time in the ready state. The “Reset Menu” will appear on the LCD.

(2)Press the button a few times to select “Fuser”.

(3)Press the OK button.

The “1. Reset 2. Exit” will appear on the LCD.

(4)Press the 1 button when resetting the page counter of the fuser unit. Press the 2 button if not resetting.

(5)The “Fuser / Accepted” will appear on the LCD if pressing the 1 button. The page counter of the fuser unit is reset, and the number of replacement times is increased by one. Then, the machine returns to the ready state.

If pressing the 2 button, the machine returns to the Fuser and you need to press Stop/Exit button to go back to the ready state without performing any operation.

5-38

Confidential