Selector No. | Function |
| Setting and Specifications | |||
|
|
|
|
|
|
|
1 |
| First transmission speed choice | No. 1 | 2 | 3 |
|
| No. 4 | 5 | 6 |
| ||
| for fallback |
| ||||
3 |
| 0 | 0 | 0: 2,400 bps | ||
|
| |||||
|
| 0 | 0 | 1: 4,800 bps | ||
|
|
| ||||
|
|
| ||||
|
|
| 0 | 1 | 0: 7,200 bps | |
4 |
| Last transmission speed choice | 0 | 1 | 1: 9,600 bps | |
| 1 | 0 | 0: 12,000 bps | |||
| for fallback | 1 | 0 | 1: 14,400 bps | ||
6 |
| |||||
|
| |||||
|
| 1 | 1 | 0: 14,400 bps | ||
|
|
| ||||
|
|
| 1 | 1 | 1: 14,400 bps | |
|
|
|
|
| ||
7 |
| V.34 mode (Not used.) | 0: Permitted | 1: Prohibited | ||
|
|
|
|
| ||
8 |
| V.17 mode | 0: Permitted | 1: Prohibited | ||
|
|
|
|
|
|
|
Note:
Selector 7 takes effect only in models supporting V.34 mode.
- Selectors 1 through 6: First and last choices of transmission speed for fallback
These selectors are used to set the MODEM speed range. With the first transmission speed choice specified by selectors 1 through 3, the machine attempts to establish the transmission link via the MODEM. If the establishment fails, the machine automatically steps down to the next lowest speed and attempts to establish the transmission link again. The machine repeats this sequence while stepping down the transmission speed to the last choice specified by selectors 4 through 6.
If the MODEM always falls back to a low transmission speed (e.g., 4,800 bps), set the first transmission speed choice to the lower one (e.g., modify it from 12,000 bps to 7,200 bps) in order to deactivate the
Generally, to save the transmission time, set the last transmission speed choice to a higher one.
- Selector 7: V.34 mode (Not used.)
If this selector is set to “0,” selectors 5 through 8 on the WSW38 through WSW40 and on WSW41, will become effective.