< WSW58 >

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

No. 1

2

3

 

 

0

0

0: Invalid

1

Prevention of line interrupt

0

0

1: 10 %

0

1

0: 20 %

during ICM recording (ratio of

guard tone response time to call

0

1

1: 30 % (Default)

3

end tone ON time)

1

0

0: 40 %

(Not used.)

 

1

0

1: 50 %

 

 

 

 

1

1

0: 60 %

 

 

1

1

1: 70 %

 

 

 

 

 

4

 

 

 

 

Not used.

 

 

 

7

 

 

 

 

 

 

 

 

 

8

Improvement of DTMF

0: OFF

1: ON

detecting function

 

 

 

 

 

 

 

 

 

Note:

Selectors 1 through 3 are applicable only to models equipped with built-in TADs.

-Selectors 1 through 3: Prevention of line interrupt during ICM recording (ratio of guard tone response time to call end tone ON time) (Not used.)

If an ICM tone is detected as a call end tone by error, this machine will release the line even during ICM recording. To avoid this problem, change the setting for the ratio of guard tone response time to the call end tone ON detection time.

If the actual percentage of guard tone response time is greater than the percentage set by selectors 1 through 3, this machine will judge that the call end tone has not yet been detected and will continue ICM recording.

< WSW59 >

Selector No.

Function

Setting and Specifications

 

 

 

 

USB serial number (SN)

0: USB serial number transmitted/ USB

1

serial number not transmitted

transmission enabled/disabled

 

1: Frame length selection

 

 

 

 

 

2

 

 

Not used.

 

8

 

 

 

 

 

- Selector 1: Frame length selection

This is intended to prevent the problem of a continued increase in USB ports when serial numbers are transmitted from the MFC to a Windows Vista-based PC.

It is intended only to prevent a problem specific to Windows Vista; its default setting is “0: USB SN enabled.”

App. 1-62