SCANNER ERROR
Detection error of horizontal scanning edge reduction in scanning area setting * This error is indicated on the LCD in the maintenance mode.
Error code B6SCANNER ERROR
Detection error of horizontal scanning edge magnification in scanning area setting * This error is indicated on the LCD in the maintenance mode.
Step | Cause | Remedy |
1 | White tape dirty of FB unit | Clean the white tape. |
|
|
|
2 | CCD unit failure | Replace the CCD unit. |
|
|
|
3 | Main PCB failure | Replace the main PCB ASSY. |
SCANNER ERROR
Scanning light adjustment error is detected.
* This error is indicated on the LCD in the maintenance mode.
Step | Cause | Remedy |
|
|
|
1 | CCD unit failure | Replace the CCD unit. |
2 | Main PCB failure | Replace the main PCB ASSY. |
SCANNER ERROR
White level data error
* This error is indicated on the LCD in the maintenance mode.
Step | Cause | Remedy |
|
|
|
1 | CCD unit failure | Replace the CCD unit. |
2 | Main PCB failure | Replace the main PCB ASSY. |