Completely blank

User Check

- Replace the toner cartridge or drum unit with a new one.

Step

Cause

Check

Result

Remedy

 

 

 

 

 

1

Developing bias

Are the electrodes on the

Yes

Clean both electrodes.

 

voltage

drum unit and machine

 

 

 

conduction failure

body dirty?

 

 

 

 

 

 

 

2

Scanner harness

Is the scanner harness

No

Reconnect the scanner

 

connection failure

connected securely?

 

harness.

 

 

 

 

 

3

Engine PCB

Is the problem solved after

Yes

Replace the engine PCB

 

failure

replacing the engine PCB

 

ASSY.

 

 

ASSY?

 

 

 

 

 

 

 

4

Laser unit failure

Is the problem solved after

Yes

Replace the laser unit.

 

 

replacing the Laser unit?

 

 

5

Transfer HVPS

Is the problem solved after

Yes

Replace the transfer

 

PCB failure

replacing the transfer

 

HVPS PCB ASSY.

 

 

HVPS PCB ASSY?

 

 

 

 

 

 

 

6

Charge HVPS

Is the problem solved after

Yes

Replace the charge

 

PCB failure

replacing the charge

 

HVPS PCB ASSY.

 

 

HVPS PCB ASSY?

 

 

 

 

 

 

 

Image distortion

Step

Cause

Check

Result

Remedy

1

Laser unit not

Is the laser unit

No

Assemble the laser unit

 

assembled

assembled into the

 

correctly and secure the

 

correctly

machine securely?

 

screw.

 

 

(Check if there is no gap.)

 

 

2

Incorrect radiation

Is the problem solved after

Yes

Replace the laser unit.

 

angle of scanner

replacing the laser unit?

 

 

 

diode

 

 

 

 

Scanner motor

 

 

 

 

rotation failure

 

 

 

 

 

 

 

 

1-45

Confidential