Error code 38
Print Unable 38
Turn the power off and then back on again.
THM (Thermistor) sensor failure
Error code 39
Print Unable 39
Turn the power off and then back on again.
HUM (Humidity) sensor failure
Step | Cause | Remedy |
|
|
|
1 | Harness connection failure of | Check the harness connection of the THM/HUM |
| THM/HUM sensor | sensor and reconnect it. |
2 | THM/HUM sensor failure | Replace the THM/HUM sensor holder ASSY. |
3 | Engine PCB failure | Replace the engine PCB ASSY. |
Print Unable 3B
Turn the power off and then back on again.
Main PCB RAM failure
Step | Cause | Remedy |
|
|
|
1 | Main PCB failure | Replace the main PCB ASSY. |
Error code 56
Cover is Open
Close the Back Cover.
Back cover opened
User Check
- Check if the back cover is closed correcty.
Step | Cause | Remedy |
|
|
|
1 | Back cover switch failure | Check the sensor performance following the |
|
| procedure described in “Maintenance mode 32”. |
2 | Harness connection failure of | Check the harness connection of the back cover |
| back cover switch ASSY | switch ASSY and reconnect it. |
3 | Part pressing the back cover | Replace the back cover switch ASSY. |
| switch is broken, which is |
|
| provided at the right side of |
|
| back cover on the inside. |
|
4 | Engine PCB failure | Replace the engine PCB ASSY. |
Confidential |