(8)Disconnect the Connector (CN7), and remove the two bind B M3x8 Taptite screws, and then remove the Density sensor.

Note:

Do not touch the Variable resistor on the back of the Density sensor.

Variable resistor

Density sensor

Taptite, bind B M3x8

Connector

CN7

Registration relay PCB ASSY

Transfer HVPS PCB unit

Fig. 3-37

(9)Disconnect the Flat cable (CN2) and three Connectors (CN6, CN9, CN13) from the Registration relay PCB ASSY.

Note:

-After disconnecting the flat cable(s), check that each cable is not damaged at its end or short-circuited.

-When connecting the flat cable(s), do not insert it at an angle. After insertion, check that the cable is not at an angle.

 

CN9

 

CN13

 

CN6

Transfer HVPS PCB unit

CN2

Registration relay PCB ASSY

Fig. 3-38

3-51

Confidential