(8)Disconnect the Connector (CN7), and remove the two bind B M3x8 Taptite screws, and then remove the Density sensor.
Note:
Do not touch the Variable resistor on the back of the Density sensor.
Variable resistor
Density sensor
Taptite, bind B M3x8
Connector
CN7
Registration relay PCB ASSY
Transfer HVPS PCB unit
Fig.
(9)Disconnect the Flat cable (CN2) and three Connectors (CN6, CN9, CN13) from the Registration relay PCB ASSY.
Note:
-After disconnecting the flat cable(s), check that each cable is not damaged at its end or
-When connecting the flat cable(s), do not insert it at an angle. After insertion, check that the cable is not at an angle.
| CN9 |
| CN13 |
| CN6 |
Transfer HVPS PCB unit | CN2 |
Registration relay PCB ASSY
Fig.