Dark

User Check

-Check the machine’s environment. High temperature and high humidity conditions can cause this problem.

-Replace the toner cartridge or drum unit with a new one.

-Implement calibration from the control panel.

Step

Cause

Check

Result

Remedy

1

Corona wire

Are the electrodes on the

Yes

Clean both electrodes.

 

conduction failure

drum unit and machine

 

 

 

 

body dirty?

 

 

2

Dirt on belt unit

Are the electrodes on the

Yes

Clean both electrodes.

 

electrode

belt unit and machine

 

 

 

 

body dirty?

 

 

3

Transfer HVPS

Is the problem solved

Yes

Replace the transfer

 

PCB failure

after replacing the transfer

 

HVPS PCB ASSY.

 

 

HVPS PCB ASSY?

 

 

4

Charge HVPS

Is the problem solved

Yes

Replace the charge

 

PCB failure

after replacing the charge

 

HVPS PCB ASSY.

 

 

HVPS PCB ASSY?

 

 

5

Engine PCB

Is the harness connected

Yes

Replace the engine PCB

 

failure

between the HVPS PCB

 

ASSY.

 

 

and engine PCB

 

 

 

 

correctly?

 

 

Poor fixing

User Check

- Replace the drum unit with a new one.

- Replace the toner cartridge with a new one. - Implement calibration from the control panel.

Step

Cause

Check

Result

Remedy

 

 

 

 

 

1

Fuser unit failure

Is the problem solved

Yes

Replace the fuser unit.

 

 

after replacing the fuser

 

 

 

 

unit?

 

 

2

Low-voltage

Is the problem solved

Yes

Replace the PS PCB unit.

 

power supply PCB

after replacing the PS

 

 

 

failure

PCB unit?

 

 

3

Transfer HVPS

Is the problem solved

Yes

Replace the transfer

 

PCB failure

after replacing the transfer

 

HVPS PCB ASSY.

 

 

HVPS PCB ASSY?

 

 

4

Charge HVPS

Is the problem solved

Yes

Replace the charge

 

PCB failure

after replacing the charge

 

HVPS PCB ASSY.

 

 

HVPS PCB ASSY?

 

 

5

Engine PCB

Is the problem solved

Yes

Replace the engine PCB

 

failure

after replacing the engine

 

ASSY.

 

 

PCB ASSY?

 

 

1-44