CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS, REQUIRED AFTER PARTS REPLACEMENT

1. IF YOU REPLACE THE MAIN PCB

< What to do when replacing the main PCB >

Rewriting the Firmware (Main Firmware, Sub Firmware (PCL/PS))

EEPROM Parameter Initialization of the Main PCB (Maintenance Mode: Code 01)

Operational Check of Control Panel Button (Maintenance Mode: Code 13)

Operational Check of Sensors (Maintenance Mode: Code 32)

Acquisition of White Level Data and Set the CCD Scanner Area (Maintenance Mode: Code 55)

EEPROM Customizing of the Main PCB (Maintenance Mode: Code 74)

Setting the Serial Number Performing the Auto Registration

< Which parts to use >

Main PCB: The table below shows the ROM type.

Main PCB

ROM 0

(16 Mbyte)

Main Firmware

(For a spare parts)

 

 

(Controller Program, Network Program)

 

 

 

 

 

ROM 1

(8 Mbyte)

Sub Firmware (PCL/PS)

 

 

 

(Emulation, Font data)

< What you need to prepare >

(1)

Computer (WindowsXP/2000)

 

 

Create a folder on the C drive, for example:- (AC FIRMWARE)

(2)

A USB flash memory drive

 

(3)

The Firmware

 

 

 

 

 

Main Firmware:

LZXXXX_$.djf

 

LZ1092_A.djf

LZXXXX: First six digits are a parts number of the

 

Sub Firmware (PCL/PS):

firmware.

 

LZ0828_A.djf

$: Alphabet representing the revision of the firmware.

 

 

 

 

 

(4)The Maintenance Tool (Mainte.EXE)

Copy it into the folder that has been created on the C drive. Extract the copied file and run “brmainte.exe” file by double-clicking it.

(5)A USB cable

(6)The Download Utility (FILEDG32.EXE)

Copy it into the folder that has been created in the C drive.

(7)The Brother Maintenance USB Printer Driver

Copy it into the folder that has been created on the C drive and extract the copied file.

4-1

Confidential