Installation
Table 2-6: Complete List of Variables
Variable | Function |
|
|
INSTALLER_UI {should be equal to silent} | Use this variable to indicate the install type. |
|
|
CHOSEN_INSTALL_SET {agent, SRA, | Use this variable to select which agent |
agentSRA} | component to install. |
| • Use agent to install the System Agent. |
| • Use SRA to install the Serial Relay Agent. |
| • Use agentSRA to install both the System |
| Agent and Serial Relay Agent. |
|
|
USER_INSTALL_DIR {Divisions in the file structure between directories should be indicated with the symbol '$/$'.
Example: C:$/$hprpm}
Use this variable to indicate the path to which the agent component is to be installed.
USER_INPUT_CERT_PW_1 {password needed if CHOSEN_INSTALL_SET = agent or CHOSEN_INSTALL_SET = agentSRA; should be equal to USER_INPUT_CERT_PW_2}
Use this variable to input the SSL certificate password that will be generated during the install.
USER_INPUT_SRA_COM {Communications Port Number the UPS is connected to, needed if CHOSEN_INSTALL_SET = SRA or CHOSEN_INSTALL_SET = agentSRA}
Use this variable to input the COM port number to which the UPS is connected.
USER_INPUT_RESULTS_START_1 {this variable is needed to start the services installed; it should be equal to Start RPM Services?}
Use this variable to start the HP Rack and Power Manager service.
Example 2-1: Silent System Agent Installation
INSTALLER_UI = silent
CHOSEN_INSTALL_SET = agent
USER_INSTALL_DIR = c:$\$Program Files$\$HPRPM
USER_INPUT_CERT_PW_1 = Admin
USER_INPUT_RESULTS_START_1 = Start RPM Services?
HP Rack and Power Manager User Guide |