MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Programming with SPM
Page2-3Installing the SPM Software
2
Direct local connection, if the PC is more than 50 ft. from the control unit.
355AF adapter
EIA crossover cable
Two Z3A2 Asynchronous Data Units (ADUs)
ADU crossover cable
400B2 power adapter
2012D transformer
BR1A-4P adapter and either a 102 connecting block or 103
connecting block
248B adapter
Eight-position wall jacks
Four-pair plug-ended cable
—D8W cords
D6AP power cord
EIA-232-D cables
Modem (local or remote) connection
A modem that supports 1200- or 2400-bps connections
In addition, a parallel printer is useful for reports (the PC needs a parallel port for
the connection).
NOTE:NOTE:NOTE:
SPM uses Interrupt 4 and I/O address 3F8 for COM1. It uses Interrupt 3
and I/O address 2F8 for COM2.
Installing the SPM Software 2
Before you install or run SPM, use on a DOS PC (see your operating
system guide) to make a backup copy of the SPM diskett e and sto re the o rig inal i n
a safe place. Use the backup copy to run the installation program.
For installing SPM on a DOS PC, follow the appropriate instructions in the next
section of this book.
NOTE:NOTE:NOTE:
If your PC does not have a hard disk, you do not need to run the installation
program. Go to “Initializing the SPM Software” on page 2–9.