MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Programming Procedures
Page4-48Lines and Trunks
4
NOTES:
1. If the disconnect interval is longer than the telephone company setting,
the line is not released when a caller on hold hangs up.
2. Do not program a short interval unless the local telephone company’s
central office is the crossbar type.
3. Do not program a reliable disconnect for lines/trunks with a short hold
disconnect interval. This can cause active calls as well as lines/trunks on
hold to be disconnected. See “Disconnect Signaling Reliability ” on page
42.
For more information on Hold Interval Disconnect and Reliable and Unreliable
Disconnect, see the
Feature Reference.
Summary: Hold Disconnect Interval 4
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 2c, System Numbering: Line/Trunk Jacks
Factory Setting Long interval (450 ms)
Valid Entries Long interval, Short interval
Inspect No
Copy Option No
Console Procedure To program a single line/trunk:
More→ →Select entry
modeDial no. of the line/trunk → →
To program a block of lines/trunks:
More→ →Select block of
lines/trunksToggle LED On/Off → →
PC Procedure To program a single line/trunk:
→ → →Type no. of the line/trunk
→ →
To program a block of lines/trunks:
→ →Select block of lines/trunks
Toggleletter On/Off→→→