MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page3-12System Renumbering
3
Use the single renumbering procedure any time the extension numbers you are
changing
from
or
to
are not sequential.
Block renumbering is quicker, but you can use block renumbering only when the
extension numbers you are changing
from and to are sequential.
When trunk or extension modules are removed from the co ntrol unit, the
remaining modules must be rearranged so that no empty slots remain. The
system does not acknowledge any modules installed after an empty slot;
therefore, if the system is renumbered, extensions are not assigned to extension
jacks after the empty slots.
NOTE:NOTE:NOTE:
Figure 3–1, Figure 3–2, and Figure 3–3 show the default settings in the
gray spaces. Extensions can be renumbered to any number shown in the
white spaces.
Figure 3–1. 2-Digit Numbering
0Operator Console (not flexible) 0
1Extensions 10−19
2Extensions 20−29
3Extensions 30−39
4Extensions 40−49
5Extensions 50−59
6Extensions 60−66 Extra
Extensions
6700−6842
6843−
6849 Extra MFMs/
Terminal Adapters
6850−6992
6993−
6999
7Main Pool
70 MFMs/
Terminal Adapters
710−766
767−
769 Calling Groups
770–791,7920−7929 Paging
Groups
793−799
8800*Trunks 801−880 Park
881−888 889
†
Pools
890−899
9 ARS Access (Hybrid/PBX Mode) / Idle Line Access 9
*
Listed Directory Number (QCC Queue)
†
Remote Access
NOTE: “0” and “10” are the same station.