MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Programming Procedures
Page4-195PRI Facilities
4
Test Telephone Number 4
Use this procedure to assign a test line or trunk telephone number for each 100D
module installed in the control unit.
The number assigned to the test line/trunk must be different from t he numbers
assigned to other channels in the same B-channel group. It must be identical to
the number provided by the PRI service provider.
Summary: Test Telephone Number 4
Programmable by System Manager
Mode Hybrid/PBX, Key
Idle Condition Not required
Planning Form Form 3b, Incoming Trunks: DS1 Connectivity (100D module)
Factory Setting Not applicable
Valid Entries Telephone number of up to 12 digits
Inspect No
Copy Option No
Console Procedure → → Dial slot no.
DropDial telephone no. → →
PC Procedure → → →Type slot no.→ → +
Typet elephone no.→→→
Procedure: Test Telephone Number 4
Console Display/Instructions Additional Information PC
Select the Lines and Trunks menu.