MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page4-264Extensions
4
Fax Machines 4
Use this procedure to identify the extension jacks used to connect fax machines.
In addition, you can specify the extensions to receive a message-waiting
indication (MWI) when a fax transmission is received, and specify the length of
time before the system registers that a fax has arrived and sends the message-
waiting indication.
NOTE:NOTE:NOTE:
Do not use this procedure for fax machi ne s conn ected to analog multiline
telephones with a General Purpose Adapter (GPA). In a GPA configuration,
features cannot be assigned to the fax independently of the t elephone.
See Chapter 3, “Common Administrative Procedures,” for detailed programming
procedures.
Summary: Fax 4
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 4b, Analog Multiline Telephone
Form 4d, MLX Telephone
Form 4e, MFM Adjunct: MLX Telephone
Form 4f, Tip/Ring Equipment
Form 5a, Direct-Line Console (DLC): Analog
Form 5b, Direct-Line Console (DLC): Digital
Form 5c, MFM Adjunct: DLC
Factory Setting 10 seconds
Valid Entries 0 to 30 seconds
Inspect Yes
Copy Option No
Console Procedure → → Dial ext. no.
→ →Dial fax machine ext. no.
Dial MWI ext. no.→ → Drop
Dial no. of seconds → →
PC Procedure → → →Type ext. no.→→→→
Type fax machine ext. no.→ →Type MWI ext. no.
→ → + Type no. of seconds
→ →