MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page4-275Extensions
4
Extension Selected Is System Programming Port 4
This message appears if you have chosen an extension that has been
programmed as a system programming port, which is not permitted as the CTI link
port. You must choose another port for the CTI link extension.
NOTE:NOTE:NOTE:
You should choose a module other than the one that has the system
programming port so that you can still perform maintenance and system
programming when the board with the CTI link extension is busied-out.
MLX Port Module Contains Firmware Vintage 29 4
This message appears when the port that you are programming as the CTI link is
on an MLX module with firmware vintage 29. Modules with this firmware vintage
do not work correctly with the CTI link. You must either choose a port on a board
with firmware vintage other than 29 or replace the module with a module that has
a firmware vintage other than 29.