MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page4-326System Features
4
Copy Option No
Console Procedure → → or
→ →
PC Procedure → → or →→→
SMDR Call Length 4
Use this procedure to set the minimum time length of a call before it is recorded
on SMDR call reports.
NOTES:
1. If the majority of lines/trunks are PRI, the recommended call length is 1.
See the
Feature Reference
for more information.
2. The outbound call of a Centrex Transfer via Remote Call Forwarding call
will not be recorded unless the minimum time length is set to zero (0).
The inbound Centrex call to the Principle User who has Centrex
Transfer via Remote Call Forwarding will also not be recorded unless
the minimum time length is 0.
Summary: SMDR Call Length 4
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 8a, System Features
Factory Setting 40 seconds
Valid Entries 0 to 255 seconds
Inspect No
Copy Option No
Console Procedure → → DropDial no. of
seconds → →
PC Procedure → → + Type no. of seconds
→ →