MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page4-378Automatic Route Selection
4
Console/Display Instructions Additional Information PC
Enter a pool dial-out code of up to 3 digits on whi ch t o rou t e ca ll s.
Continue to enter pool dial-out code(s) for ano th er ro ute or go to Step 5.
Select .
Return to Step 3. The next route is
displayed on Line 1.
Save your entry.
Select .
Return to the System Programming menu.
Select twice.
Facility Restriction Level 4
Use this procedure to assign a Facility Restriction Level (FRL) to each route. The
FRL ranges from 0 (least restrictive) to 6 (most restrictive) and is used to restrict
user access to the route. The FRL assigned to extensions and remote access
users is the opposite of the FRL assigned to routes, where 0 is the most restrictive
and 6 is the least restrictive.
NOTE:NOTE:NOTE:
Pool routes must be programmed before you assign Facility Restriction
Levels.
Facility Restriction Levels are assigned to Tables 1 through 18. Tables 17 and 18,
the Default Toll and Default Local tables respectively, cannot be changed.
xx
= table number entered in Step 1
x
= route number entered in Step 1
Dial or type [
nnn
].