MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Programming Procedures
Page4-203PRI Facilities
4
Terminal Equipment Identifier 4
Use this procedure to assign the link layer address of a piece of equipment
connected to each D-channel. Normally, only one piece is connected and the
system assumes that the Terminal Equipment Identifier (TEI) is 0.
!CAUTION:
!CAUTION:
The value of the TEI rarely has to be changed. Check with your Lucent
Technologies representative before changing this value.
Summary: Terminal Equipment Identifier 4
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 3b, Incoming Trunks: DS1 Connectivity (100D module)
Factory Setting 0
Valid Entries 0 to 63
Inspect No
Copy Option No
Console Procedure → → → →Dial slot no.
DropDial new ID no.
PC Procedure → → → →Type slot no.→ → +
Type new ID no.→→→→
Procedure: Terminal Equipment Identifier 4
Console Display/Instructions Additional Information PC
Select the Lines and Trunks menu.