MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page3-171Optional Group Calling Features
3
Overflow coverage can be provided only by calling groups or the QCC queue
(Hybrid/PBX only), not by individual extensions.
A calling group or the QCC queue (Hybrid/PBX only) can provide overflow
coverage for more than one calling group; however, which group’s calls go to an
available member in the overflow calling group is unpredictable.
The factory-set extension number for the QCC Listed Directory Number is 800.
Summary: Group Calling Overflow and
Thresholds 3
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 7d, Group Calling
Factory Setting Overflow coverage: none
Threshold: 1 call
Timeout: 0 sec
Prompt-based overflow: Disabled
Valid Entries Overflow coverage: Backup extension number
Threshold: 1 to 99 calls
Timeout: 0 to 900 seconds
Prompt-based overflow: Enabled, Disabled
Inspect No
Copy Option No
Console Procedure More → →
Dial calling group ext. no.→ →Dial overflow ext. no.
→ →DropDial no. of
calls→ → Drop
Dial no. of seconds→ →
or → → →
PC Procedure → → →Type calling group ext. no.
Type overflow ext. no.→→→ + Type
no. of calls→→→ + Type no. of seconds
or →→→→