MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Programming Procedures
Page4-88DS1 Facilities
4
If the type is T1 and the type of channel emulation is tie trunk, you must specify
whether the lines/trunks are TIE-PBX, Toll, or Switched 56 Data service. The valid
settings are as follows:
TIE-PBX. Select when emulated tie trunks are used to connect to another
communications system (such as PBX or Centrex). The transmit/receive
parameter is set to 0/4.
Toll. Select when emulated tie trunks are used for ASN services (such as
Megacom, Megacom 800, or Software Defined Network). The transmit/
receive parameter is set to 0/6.
NOTE:
The parameters listed in the two above items are for releases prior to
Release 6.0. In Release 6.0 and later systems, the transmit/receive
gains are determined by the call constituents.
TIE - S56 Data. Select when emulated tie trunks are used for Switched 56
Data Service. Switched 56 Data Service is available only in Release 4.0
and later. The transmit/receive parameter is set to 0/0.
If the type is T1 and S56 Data Network Service is selected, you must specify the
following parameters (Switched 56 Data Service is available only in Release 4.0
and later):
Direction. Specifies whether the trunk operates in one- or two-way
direction. For one-way trunks, Outgoing Only or Incoming Only must also
be specified.
Trunk Seizure Type. Trunk seizure type is administered independently for
incoming or outgoing directions. Select one of the following: Wink Start,
Delay Start, or Automatic Start.
Answer Supervision Time. The time in milliseconds the answer
supervision signal must be present to be considered valid.
Disconnect Time. The time in milliseconds the disconnect signal must be
present to be considered valid.
Dial Mode. Select either Rotary or Touch-Tone. Dial mode is set
independently for incoming or outgoing directions (Inmode or Outmode).
NOTE:
Touch-Tone receivers are required on the far-end switch when the
setting is Touch-Tone.
Table 4–1 shows the factory setting for each S56 Data Network Service option
and the valid range for each threshold.