MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page4-451Memory Card
4
Card Removed after Confirmation 4
The memory card was removed from the PCMCIA interface slot while the restore
was in progress. The restore is aborted and the system performs a System Erase
(frigid start). You must reinsert the memory card and repeat the restore procedure.
Wrong System Programming Port 4
The system programming port is not set to the same system programming port as
that set in the backup file. The restore is aborted. Use the Inspect feature to view
the port of the file on the card. Change the system programming port to match the
port shown on the card (see “System Programming Position Assignment” on page
4–4) and repeat the restore procedure.
Release Mismatch 4
This screen only appears if you are upgrading from Release 3.0 or higher and the
releases are not compatible.
n
= filename selected
xxxx
= system programming port
extension
n
= filename selected

X.Y

= release number