MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Programming Procedures
Page4-87DS1 Facilities
4
Console/Display Instructions Additional Information PC
Assign or remove the switch identifier.
Select or
or
You may continue to assign or remove switch
identifiers from additional lines/trunks by
repeating Steps 2 through 7.
Return to the System Programming menu.
Select three times.
DS1 Facilities 4
Use the procedures in this section to program the following options for DS1
(digital signal level 1) facilities (T1 or PRI) connected to a 100D (DS1) m odule:
Type of DS1 facility
—T1
ISDN (Integrated Services Digital Network) Primary Rate Interface
(PRI)
Switched 56 Dial Plan Routing
Frame Format
Zero Code Suppression
Signaling Mode
Line Compensat i on
Channel Service Unit

Type of DS1 Facility 4

Use this procedure to specify the type of facility (T1 or PRI) connected to a 100D
(DS1) module. If T1 type is programmed, and the channels are used for emulation
and/or AT&T Switched Network (ASN), you must specify the type of channel
emulation.
NOTE:NOTE:NOTE:
In Release 6.0 and later systems, you may order a point-to-point T1 circuit
in order to provide amplification but not switching for a PRI tandem trunk
that carries calls over long distances. PRI tandem trunks are preferable to
T1 tandem trunks. Consult your Lucent Technologies representative for
advice.