MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page4-294QCC Optional Features
4
Console Procedure → → →Drop
Dial no. of seconds → →
PC Procedure → → → + Type no. of seconds
→ →
Calls-In-Queue Alert 4
Use this procedure to specify whether each QCC operator is notified (with a single
beep) when a new call enters the QCC queue.
Summary: Calls-In-Queue Alert 4
Programmable by System Manager
Mode Hybrid/PBX
Idle Condition Not required
Planning Form Form 6a, Optional Operator Features
Factory Setting Disable
Valid Entries Enable, Disable
Inspect Yes
Copy Option No
Console Procedure → → →Dial ext. no.
or
→ →
PC Procedure → → →Type ext. no.→ → or
→ →
QCC Operator to Receive Call Types 4
Use this procedure to specify which QCC operators receive the following types of
calls:
Dial 0 calls (internal calls to the system operator)
DID calls to invalid destinations (unassigned extension numbers)
Calls to the Listed Directory Number (extension for the QCC queue)
Calls programmed to return to the QCC queue (returning from directing,
camped-on, held calls, and operator parked calls)
Group Coverage calls
Forward/Follow Me calls
The QCC queue can be a receiver for the maximum number of coverage
groups (30).