MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page3-230System Features
3
Console/Display Instructions Additional Information PC
Save your entry.
Select .
Return to the System Programming menu.
Select twice.
Recall Timer 3
Use this procedure to designate the length of the timed flash that is sent when
Recall is used to disconnect a call and get a new dial tone without hanging up.
Both the interval of the timed flash and how Recall works depend on the type of
telephone and system operating mode.
The recall timer should be reset if multiline telephone users experience either of
the following problems:
Nothing happens when the user presses the Recall button on an outside
call. This indicates that the interval is too short and should be increased to
650 milliseconds or one second.
In a system operating in Behind Switch mode, the call is disconnected
when the user presses the Recall button on an outside call. Th is indicates
that the interval is too long and should be decreased to 350 milliseconds.
Summary: Recall Timer 3
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 8a, System Features
Factory Setting 450 ms
Valid Entries 350 ms, 450 ms, 650 ms, 1 second
Inspect No
Copy Option No
Console Procedure More→ →Select time
PC Procedure → →Select time→ →