MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Common Administrative Procedures
Page3-182Optional Group Calling Features
3
Console/Display Instructions Additional Information PC
Return to the System Programming menu.
Select twice.

Group Calling External Alert for

Calls-In-Queue Alarm 3
Use this procedure to designate the external alert de vice used to notify calling
group members when the number of calls in the queue reaches the programmed
Threshold 3.
Only one external alert device can be designated for each calling group. Since the
external alert signal is continuous, it is recommended that only light-type external
alert devices be designated for the Calls-in-Queue alarm.

Summary: Group Calling External Alert for

Calls-In-Queue Alarm 3
Programmable by System Manager
Mode. All
Idle Condition Not required
Planning Form Form 7d, Group Calling
Factory Setting Not applicable
Valid Entries Extension number
Inspect No
Copy Option No
Console Procedure More
Dial calling group ext. no.→ →Drop
Dial ext. no. for alert → →
PC Procedure → → →Type calling group ext. no.
+ Type ext. no. for alert→→→