MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111 Issue 1
February 1998
Customer Support Information
PageA-12Toll Fraud Prevention
A
Any time a call appears to be suspicious, call the Lucent Technologies
GBCS Fraud Intervention Center at 1 800 628-2888 (fraud intervention for
System 25, PARTNER® and MERLIN® systems).
Customers should also take advantage of Lucent Technologies monitoring
services and devices, such as the NetPROTECTSM family of fraud
detection services, CAS with HackerTracker®, and CAT Terminal with
Watchdog. Call 1 800 638-7233 to get more information on these Lucent
Technologies fraud detection services and products.

Security Risks Associated w ith Transferring

through Voice Messaging Systems 1

Toll fraud hackers try to dial into a voice mailbox and then execute a transfer by
dialing . The hacker then dials an access code (either for Automatic Route
Selection or a pooled facility code) followed by the appropriate digit string to either
direct dial or access a network operator to complete the call.
NOTE:
In Release 3.1 and later systems, all extensions are initially and by default
restricted from dial access to pools. In order for an extension to use a pool
to access an outside line/trunk, this restriction must be removed.
Preventive Measures 1
Take the following preventive measures to limit the risk of unauthorized transfers
by hackers:
Outward restrict all MERLIN LEGEND voice mail port extensions. This
denies access to facilities (lines/trunks). In Release 3.1 and later systems,
voice mail ports are by default outward restricted.
As an additional security step, network dialing for all extensions, including
voice mail port extensions, should be processed through ARS us ing dial
access code .
!SECURITYlALERT:

The MERLIN LEGEND system ships with ARS activated with all

extensions set to Facility Res triction Level 3, allowing all international

calling. To prevent toll fraud, ARS Facility Restriction Levels (FRLs)

should be established using:

FRL 0 for restriction to internal dialing only

FRL 2 for restriction to local network calling only

FRL 3 for restriction to domestic long distance (excluding

area code 809 for the Dominican Republic as this is part of

the North American Numbering Plan, unless 809 is required)

FRL 4 for international calling