Device Management

Column

Description

 

 

RAS port

The RAS (Registration, Admission and Status) channel port number. Leave

 

set to 1719 unless you know the gatekeeper is using a non-standard port

 

number.

 

 

Prefix range

The dial string prefix or prefix range for which the external gatekeeper is

 

responsible.

 

Enter a single prefix (44), a range of prefixes (44-47), multiple prefixes

 

separated by commas (44,46), or a combination (41, 44-47, 49).

 

If your dial plan uses the Dial services by prefix dial rule (in the default dial

 

plan) to route calls to services, all dial strings beginning with an assigned

 

prefix are forwarded to this gatekeeper for resolution.

 

If your dial plan instead uses a rule that you create to apply the Resolve to

 

external gatekeeper action, there is no need to specify a prefix.

 

 

Strip prefix

If selected, the system strips the prefix when a call that includes a prefix is

 

routed to this gatekeeper.

 

 

Prefer routed

If selected (the default), the system forces all calls to this gatekeeper to routed

 

mode.

 

This setting must be enabled to avoid interoperability issues with Polycom

 

CMA and Avaya gatekeepers, and possibly others as well.

 

 

Authentication Mode

In this section, you can configure the system to send its H.235 credentials

 

when it sends address resolution requests to that gatekeeper.

 

 

Enabled

Clearing this check box lets you stop sending H.235 credentials to the

 

external gatekeeper without deleting them.

 

 

Name

The H.235 name of the Polycom RealPresence DMA system.

 

 

Password

The H.235 password for the Polycom RealPresence DMA system.

Confirm password

 

 

 

Algorithm

Select the encryption algorithm for H.235 authentication.

 

 

LRQ test

Click to test the configuration by sending an LRQ message to the external

 

gatekeeper.

 

 

Postliminary

A postliminary is an executable script, written in the Javascript language, that

 

defines dial string transformations to be applied before querying the external

 

gatekeeper.

 

 

Enabled

Lets you turn a postliminary on or off without deleting it.

 

 

Script

Type (or paste) the postliminary script you want to apply. Then click Debug

 

this script to open the Script Debugging Dialog Box for

 

Preliminaries/Postliminaries and test the script with various variables.

 

 

See also:

External Gatekeeper on page 101

Script Debugging Dialog Box for Preliminaries/Postliminaries on page 254 Device Authentication on page 261