Device Management

Edit External H.323 SBC Dialog Box

The following table describes the fields in the Edit External H.323 SBC dialog box.

Note: SBC Configuration

Only H.323 SBCs are added to the External H.323 SBC page. SIP SBCs are configured as SIP peers (see External SIP Peer on page 105) and/or on a per-site basis (see Edit Site Dialog Box on

page 285).

H.323 SBCs that are added to the External H.323 SBC page are reached by prefix-based dialing (rule 4 of the default dial plan; see The Default Dial Plan and Suggestions for Modifications on page 241).

SBCs to be reached by a dial rule using the Resolve to IP address action (rule 6 of the default dial plan) are configured on a per-site basis (see Edit Site Dialog Box on page 285).

In general, H.323 SBCs should be configured on a per-site basis, so that calls to endpoints outside the enterprise network are routed to the SBC assigned to the originating site.

Column

Description

 

 

External H.323 SBC

 

 

 

Enabled

Clearing this check box lets you stop using an external SBC without deleting

 

it.

 

 

Name

SBC unit name.

 

 

Description

The text description displayed in the External H.323 SBC list.

 

 

Address

Host name or IP address of the SBC.

 

 

Port

The SBC’s port number. Leave set to 1720 unless you know the unit is using a

 

non-standard port number.

 

 

Prefix range

The dial string prefix or prefix range assigned to this SBC. Required.

 

Enter a single prefix (44), a range of prefixes (44-47), or multiple prefixes

 

separated by commas (44,46)

 

The Dial services by prefix dial rule in the default dial plan routes calls to the

 

assigned prefix(es) to this SBC for resolution.

 

 

Strip prefix

If selected, the system strips the prefix when a call that includes a prefix is

 

routed to this SBC.

 

 

Postliminary

A postliminary is an executable script, written in the Javascript language, that

 

defines dial string transformations to be applied before querying the SBC.

 

 

Enabled

Lets you turn a postliminary on or off without deleting it.

 

 

Script

Type (or paste) the postliminary script you want to apply. Then click Debug

 

this script to open the Script Debugging Dialog Box for

 

Preliminaries/Postliminaries and test the script with various variables.

 

 

See also:

External H.323 SBC on page 120

Script Debugging Dialog Box for Preliminaries/Postliminaries on page 254

Polycom, Inc.

123

Page 123
Image 123
Polycom 3725-76302-001O manual Edit External H.323 SBC Dialog Box