Section 8: Adjustment Procedures
NOTE: Figure
LABEL GAP SENSOR ADJUSTMENT
This adjustment will require the use of a multimeter and the TP Test Module. The
NOTE: Figure
1 Remove the top, front, and left housing cover to access main circuit board (1, Figure
NOTE: Figure
2 Turn VR6 potentiometer (2) fully
NOTE: An audible click should be heard.
3 Connect test module (3) to main circuit board connector (4).
NOTE: Refer to TP Test Module Usage in the TRoubleshooting section for additional instruction on test module usage.
4Turn dial (5) on test module (3) to position number 5.
5Connect the positive (+) probe of the multimeter to pin SIG (6) on test module (3).
6Connect the negative
7Ensure the multimeter is for DC voltage reading.
8Place the label backing only in position to be read by the sensor.
9Adjust VR6 potentiometer (2) so that the multimeter value is less than 0.5 volts.
10 Replace the label backing with a label in position to be read by the sensor.
11Observe the multimeter for a value of +1.0 volts more than the prior value read.
12 Repeat steps 8 through 11 until the value is 1.0 volts.
13 Test print labels to ensure proper function.
14 Disconnect test module (3) from main circuit board (1).
15 Disconnect test module (3) from main circuit board (1) and replace housing covers.
NOTE: Figure
SATO M10e Service Manual | PN: 9001113A | Page |