Section 9: Factory Resets

11 Press the ENTER key to test print. Press the ENTER key again to stop printing.

WARNING: THIS TEST ACTIVATES ALL THE HEATING ELEMENTS ON THE PRINT HEAD AND THEREFORE SHOULD BE USED FOR TESTING PURPOSES ONLY. FULL WIDTH LABELS MUST BE USED TO PREVENT PRINT HEAD DAMAGE.

12Verify that the counters on the test print have reset to 0.0 km.

13Power Off the printer and confirm that all switches are in the Off or down position.

CLEAR HEAD COUNTERS

CAUTION: RESETTING THE PRINTER WILL CLEAR ALL REGISTERS.

1Record all dip switch positions.

2Place all dip switches in the Off position.

3Place the DSW2-4 switch in the On or up position.

4Press and hold the LINE and FEED keys while turning on the power switch.

5Release the LINE and FEED keys upon hearing a beep.

 

 

 

 

 

LCD DISPLAY:

MAINTENANCE MODE

 

 

 

DIPSW2-4 ON->OFF

 

 

 

 

 

6 Place the DSW2-4 in the Off position

 

 

 

 

 

LCD DISPLAY:

FACTORY MODE

 

 

 

 

 

7 Press the ENTER key to advance to the next display.

 

 

 

 

 

LCD DISPLAY:

COUNTER MODE - NONE

 

 

 

 

 

8 Use the Cursor keys to step from the NONE option to HEAD.

 

 

 

 

 

LCD DISPLAY:

COUNTER CLEAR - HEAD

 

 

 

 

 

9 Press the ENTER key to select the HEAD option.

 

 

 

 

 

 

LCD DISPLAY:

PRINT SIZE -

 

 

 

SMALL

LARGE

 

 

 

 

 

 

10Use the CURSOR keys to step to the desired option.

11Press the ENTER key to test print. Press the ENTER key again to stop printing.

SATO M10e Service Manual

PN: 9001113A

Page 9-2

Page 116
Image 116