Section 5: Printer Configuration

Stop Bit Selection (DSW1-4):Selects the number of stop bits to end each byte transmission.

DSW1-4

SETTING

DSW1

 

 

 

ON

Off

1

Stop Bit

 

 

 

OFF

On

2

Stop Bits

 

 

 

 

1 2 3 4 5 6 7 8

Baud Rate Selection (DSW1-5,DSW1-6):Selects the data rate (bps) for the RS232 port.

DSW1-5

DSW1-6

SETTING

DSW1

 

 

 

ON

 

 

 

 

 

 

 

 

Off

Off

9600

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

Off

On

19200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

Off

38400

 

1 2 3 4 5 6 7 8

 

 

 

 

 

 

 

 

 

 

 

 

On

On

57600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protocol Selection (DSW1-7,DSW1-8):Selects the flow control and status reporting protocols. Refer to the Interface Specifications section for more information. (* Will select the Status 2 protocol if DSW2-8 is ON).

DSW1-7

DSW1-8

SETTING

 

DSW1

Off

Off

Rdy/Bsy

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

Off

On

Xon/Xoff

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

Off

Bi-Com 3

1 2 3 4 5 6 7 8

 

 

 

 

 

 

 

 

 

 

 

 

 

On

On

Bi-Com 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 