SATO 10e service manual Power Supply Fuse Replacement, 11, Fuse Replacement

Models: 10e

1 126
Download 126 pages 27.74 Kb
Page 82
Image 82
POWER SUPPLY FUSE REPLACEMENT

Section 7: Replacement Procedures

POWER SUPPLY FUSE REPLACEMENT

The Printer has two cylindrical fuses that are wired to the power supply. If power is not being distributed throughout the printer, the fuse may require replacement.

1Switch off the printer and disconnect the power supply cord.

2Remove the top, front, and right housing covers to expose power supply (1, Figure 7-11).

NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance on housing cover removal.

3Unscrew and remove fuse caps (2) along with fuses (3).

4Remove fuses (3) from fuse caps (2) and determine their condition. Replace as required.

NOTE: The condition of a fuse may be determined by two methods; either by visually inspecting the fuse filament for voids or by using a meter to determine conductivity.

5 Reattach the right, front, and top housing covers.

NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance on housing cover installation.

1

3

2

Figure 7-11, Fuse Replacement

SATO M10e Service Manual

PN: 9001113A

Page 7-14

Page 82
Image 82
SATO 10e service manual Power Supply Fuse Replacement, 11, Fuse Replacement