Section 7: Replacement Procedures
DRIVE MOTOR REPLACEMENT
The stepper motor transmits motion to the print mechanism for precise print positioning. The energized motor provides torque to the label feed roller and the platen roller via a toothed timing belt configured on pulleys.
1 Switch off the printer and disconnect the power supply cord.
2Remove the top, front, right, left, and rear housing covers to expose printer frame (1, Figure
NOTE: Figure
2
B
A
1
4
2
5
3
Figure 7-13, Fuse Replacement
3Remove seven screws (2) securing printer frame (1) to printer base (3).
4Carefully lift away printer frame (1) and allow to rest on its front or rear side.
NOTE: Ensure the print head assembly is latched closed prior to printer frame removal.